Patient Monitor
Showing all 5 results
-
-
ECG Machine
6 Parameter 10” Patient Monitor Contec
6 Parameter 10” Patient Monitor Contec
Specifications
ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s HR: Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH RESPIRATION Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. NIBP Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode SpO2 Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. PR Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC
Accuracy: ±0.1 ºCEtCO2 Method: Sidestream or Mainstream
CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes.IBP Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. Accessories
- SpO2 test for adult fingertips (5-pin)
- NIBP adult cuff
- NIBP extension pipe
- ECG lead cable
- ECG electrode
- Temperature probe
- Power cord
SKU: n/a -
ECG Accessories
ECG Clipe For ECG Machine
ECG Clipe For ECG Machine
Description
- ECG cables with patient connection clips for wrist and ankle connections.
- Use with ECG banana-style cable is possible.
- typically as accessories for resting ECG devices
- Stress test system,
- Patient screen,
- 4 mm, CE approved
- ECG unit, etc.
SKU: n/a -
Patient Monitor
YONKER Multi Parameter Patient Monitor YK-8000C
YONKER Multi-Parameter Patient Monitor YK-8000C
Features
- Multi-parameter TET LCD color screen–8000C
- 1-inch color monitor.
- Lighter and thinner in design, user-friendly and portable.
- Evaluation of the S-T section in real-time, identification of pacemakers.
- Audio / visual warnings at 3 grades.
- Efficient defibrillator and HF knife interference resistance.
- Up to 400 NIBP teams, 6000 seconds, ECG waveform recall, 60 records of warning incidents, 7-day processing trend index.
- Built-in lithium rechargeable battery with a 2-hour capacity.
- Applicable ICU / CCU / OR wireless central monitoring system
- Size: 12* 11.4* 6.4 inches
- Weight: 8.8 lb
- Electrical specification: 100-240v AC, 50/60Hz, total input power: 70VA
- Battery: 11.1V 2200mAh rechargeable lithium battery
Standard configuration:
SpO2, PR/HR, NIBP, ECG, RESP, 2-TEMPOptional Configuration:
Nellcor SpO2, 2-IBP, ETCO2, Touch screen, Built-in Thermal PrinterStandard accessories
- Spo2 sensor adult 1 pcs
- NIBP CUFF& Hosepipe 1 set
- ECG cable 1 pcs
- Temp Sensor 1 pcs
- User manual 1 pcs
SKU: n/a