ECG Machine
Showing all 4 results
-
ECG Machine
12Channel ECG Machine Cardiolink 12T
12Channel ECG Machine Cardiolink 12T
Specifications
• Synchronous sampling system for the 12 lead ECG.
• Thermal printer with synchronized printing and 80mm print media.
• Push-button and touch-operated 5.7-inch color touch-screen.• Support for USB flash disk & SD memory; automatic measurement, calculation, analysis, & waveform freezing.
• RS232/USB data transmission to a PC.
• Patient data can be entered.
• It is possible to see and print historical data.
• Rechargeable lithium-ion battery built-in; AC/DC power conversion
• Sleep mode, which conserves energy and prolongs LCD life
• Convenient to carry, portable design with hidden handle.
• Lack of off-paper detection functionality and lead off• Adjust to a 110–230V, 50–60Hz AC power source.
SKU: n/a -
ECG Machine
6 Parameter 10” Patient Monitor Contec
6 Parameter 10” Patient Monitor Contec
Specifications
ECG Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s HR: Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH RESPIRATION Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. NIBP Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode SpO2 Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. PR Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher TEMP Channel: dual-channel
Measurement and alarm range: 0 ~ 50ºC
Resolution: 0.1 ºC
Accuracy: ±0.1 ºCEtCO2 Method: Sidestream or Mainstream
CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes.IBP Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. Accessories
- SpO2 test for adult fingertips (5-pin)
- NIBP adult cuff
- NIBP extension pipe
- ECG lead cable
- ECG electrode
- Temperature probe
- Power cord
SKU: n/a -
ECG Machine
CONTEC Touch 6-Channel ECG Machine With Touch Screen
CONTEC Touch 6-Channel ECG Machine With Touch Screen
Function
- Thermal printing method with high resolution (8 dots per millimeter), no modification required. Recording frequency: up to 150Hz.
- Constantly and constantly record the ECG waveform and annotation character (such as lead tag, resistance, paper speed, and filter status, etc.).
- Full-digital filter model, interference from the AC and EMG, and anti-baseline drift.
- Adapt the baseline, print environment, and optional lead rhythm automatically.
- To increase productivity, finish recording in AUTO mode by clicking the button once.
- Use digital signal processing to create an ECG waveform with high quality using power frequency, basic, and ECG sign EMG filters.
- The ability to automatically measure, analyze, and diagnose common ECG values, which eases the strain on doctors and increases productivity.
Performance
- Input Mode: Floating or defibrillation safety mode
- Frequency response: 0.05Hz ~ 150Hz(-3dB~+0.4dB)
- CMRR: > 60dB, > 100dB(add filter)
- Time constant: 3.2s
- Patient leakage current: < 10μA
- Calibration voltage: 1mV
- Sensitivity: 2.5, 5, 10, 20, 40 mm / mV ±5 percent, standard sensitivity: 10mm / mV±2 percent
- Noise level: < 15μVp-p
- Current input circuit: < 50nA
- Impedance input: < 50MM
- Auto record: set auto record format and mode, change leads automatically, calculate and analyze.
- Rhythm recording: set rhythm recording format and mode, measuring and analyzing automatically.
- Manual log: set record by file format, change leads manually.
- Parameters of measurement: HR, P-R, P Length, QRS Duration, T Duration, Q-T duration, Q-Tc, P Axis, QRS Axis, T Axis, R(V5), S(V1), R(V5)+S(V1)
- Paper size: 80mm(W)20m(L)
- Sampling frequency: 1000Hz
- EMG interference filter: 25Hz/35Hz (-3dB)
- Power frequency filter: AC 50Hz/60Hz(-20dB)
Paper speed: - Auto: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
- Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
- Manual: 5, 6.25, 10, 12.5, 25, 50, 100mm/s, ±5%
Accessories
- Standard:
- A lead cable
- A limb electrode
- Cheast Bulb
SKU: n/a -